Cable Cervicom Reinforced Drop CPR

Outdoor supply telephone cable for distribution and dispersion networks for subscribers according to Real Decreto 346/2011 on ICT cables, when additional mechanical protection and/or protection against the action of rodents is required

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom Reinforced Drop CPR
~\ImgCli\FOTO2_1697.jpg
Outdoor supply telephone cable for distribution and dispersion networks for subscribers according to Real Decreto 346/2011 on ICT cables, when additional mechanical protection and/or protection against the action of rodents is required
No propagador de la llama
Anti roedores
Resistente UV
Construction
1. Conductor
Bare copper wire
Diameter: 0,60mm
2. Insulation
PE (Solid polyethylene)
Identification:
· 1 pair: White, Brown
· 2 pairs: White-Brown, Red-Green
3. Composition
Twisted pairs
*Two pair cable is laid up as a star quad
4. Inner sheath
PVC (Polyvinyl chloride)
Colour: Black
5. Armour
Galvanised steel wire braid
6. Outer sheath
PVC (Polyvinyl chloride)
Colour: Black
Technical characteristics
1. Conductor resistance
65 Ohm/Km Max.
2. Resistance unbalance
Max. value: 2%
3. Insulation resistance
8000 MOhm*Km
4. Mutual capacitance
58 nF/km Max.
5. Dielectric strength
Cond-Cond: 1500 V
6. Nominal attenuation (dB/100m)
0.8 kHz: 1.20 dB/km
1.5 kHz: 1.70 dB/km
3.0 kHz: 2.30 dB/km
40 kHz: 4.5 dB/km
96 kHz: 6.0 dB/km
1000 kHz: 21 dB/km
10000 kHz: 66 dB/km
40000 kHz: 137 dB/km
7. Operating Tª (conductor)
-5°C to +70°C
8. Min. bending radius
12xD
Standards
1. Reference standards
ICT Real Decreto 346/2011
2. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
3. CPR Classification (Euroclass)
Eca
(According to UNE-EN 50575)